Felix Instruments F-750¶
Status: Supported (scoped) · Vendor: Felix Instruments / CID Bio-Science · Extensions:
.csv
The Felix Instruments (CID Bio-Science) F-750 Produce Quality Meter is a
handheld VIS-NIR spectrometer (ZEISS MMS1 silicon photodiode array, ~310-1100 nm,
3 nm sampling) used for non-destructive fruit dry-matter and internal-quality
models. Its desktop DataViewer software exports a wide CSV, so — like
VIAVI MicroNIR and Si-Ware NeoSpectra
— there is no dedicated F-750 reader: the export is decoded by the generic
csv_like wide-table reader.
Instruments & software¶
F-750 Produce Quality Meter handheld; F-750 DataViewer desktop export software.
File structure¶
DataViewer “Export” produces a comma-delimited wide table: leading
identifier / metadata / target columns, then numeric wavelength columns (nm),
one spectrum per row. The canonical public example is the Mango DMC dataset
(Anderson et al. 2020), whose columns are Set, Season, Region, Date, Type, Cultivar, Pop, Temp, DM followed by 285-1200 nm in 3 nm steps.
What nirs4all-formats extracts¶
Signals —
absorbanceover anmwavelength axis, one record per spectrum row (the published export islog(1/R)absorbance).Targets — numeric non-spectral columns (
DMdry-matter %,Pop, numericSeason) are preserved astargets.Metadata — text columns (
Set,Region,Date,Type,Cultivar,Temp) androw_indexare preserved asmetadata.
Variants & support status¶
Variant |
Status |
Notes |
|---|---|---|
DataViewer wide absorbance CSV |
Supported |
Via |
Raw-Spectra (reflectance) CSV |
Planned |
Same wide layout; reflectance signal type not yet asserted by a fixture. |
Interpolated-Spectra (2nd-derivative) CSV |
Planned |
Derivative export; no fixture yet. |
Native on-device / SD store |
Blocked |
No fixture; measurements are held on-device before DataViewer export. |
Limitations & known gaps¶
Only the wide absorbance CSV export is fixture-backed; the reflectance and derivative export modes and the native on-device format are not yet validated.
The generic reader types the signal as
absorbancefrom the wide-header layout; it does not read the DataViewer “export mode” to distinguish reflectance vs absorbance vs derivative.
Reference readers¶
Generic CSV tooling (pandas, read.table); no dedicated reference reader.
Samples & validation¶
samples/felix_f750/mango_dmc_f750_slice.csv is golden-backed in
crates/nirs4all-formats/tests/goldens/ (csv_felix_f750_mango_slice, 26 records,
306-point nm axis, 285-1200 nm). It is a CC-BY-4.0 slice of the Mango DMC
dataset (Anderson, Walsh & Subedi 2020, Mendeley 10.17632/46htwnp833.1).